Search results for "neutron beam"

showing 10 items of 10 documents

Measurement of the n-TOF beam profile with a micromegas detector

2004

A Micromegas detector was used in the neutron Time-Of-Flight (n_TOF) facility at CERN to evaluate the spatial distribution of the neutron beam as a function of its kinetic energy. This was achieved over a large range of neutron energies by using two complementary processes: at low energy by capture of a neutron via the 6Li(n,[alpha])t reaction, and at high energy by elastic scattering of neutrons on gas nuclei (argon+isobutane or helium+isobutane). Data are compared to Monte Carlo simulations and an analytic function fitting the beam profile has been calculated with a sufficient precision to use in neutron capture experiments at the n_TOF facility. http://www.sciencedirect.com/science/artic…

Elastic scatteringPhysicsNuclear and High Energy PhysicsArgonPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaBeam profileNuclear Theorychemistry.chemical_elementMicroMegas detectorNUCLEAR PHYSICSNeutron radiationNuclear physicsNeutron capturechemistryNEUTRON BEAMSNeutron cross sectionMICROMEGAS DETECTORNeutron detectionNeutron beam profilerNeutronNuclear ExperimentInstrumentationMicromegas
researchProduct

The study of neutron-rich nuclei production in the region of the closed shell N=126 in the multi-nucleon transfer reaction 136Xe+208Pb

2015

Expérience LNL/PRISMA; International audience; The unexplored area of heavy neutron rich nuclei is extremely important for nuclearastrophysics investigations and, in particular, for the understanding of the r-process ofastrophysical nucleogenesis. For the production of heavy neutron rich nuclei located along theneutron closed shell N=126 (probably the last "waiting point" in the r-process of nucleosynthesis)the low-energy multi-nucleon transfer reaction 136Xe+208Pb at Elab=870MeV was explored.Due to the stabilizing eect of the closed neutron shells in both nuclei, N=82 and N=126, andthe rather favorable proton transfer from lead to xenon, the light fragments formed in this processare well b…

Historynuclear astro-physicsProtonNuclear Theoryspektrometritchemistry.chemical_element[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyEducationNuclear physicsXenonNucleosynthesisneutron-rich nuclei0103 physical sciencesNuclear astrophysicschemical elementsNeutron010306 general physicsNuclear ExperimentOpen shellheavy neutron rich nuclei PRISMA spectrometerPhysicsneutron shellsSpectrometer010308 nuclear & particles physicsbeam linesclosed shellsComputer Science Applicationsneutron beamschemistrytime of flightAtomic physicsNucleon
researchProduct

Investigation of the Impact of Neutron Irradiation on SiC Power MOSFETs Lifetime by Reliability Tests

2021

High temperature reverse-bias (HTRB), High temperature gate-bias (HTGB) tests and electrical DC characterization were performed on planar-SiC power MOSFETs which survived to accelerated neutron irradiation tests carried out at ChipIr-ISIS (Didcot, UK) facility, with terrestrial neutrons. The neutron test campaigns on the SiC power MOSFETs (manufactered by ST) were conducted on the same wafer lot devices by STMicroelectronics and Airbus, with different neutron tester systems. HTGB and HTRB tests, which characterise gate-oxide integrity and junction robustness, show no difference between the non irradiated devices and those which survived to the neutron irradiation tests, with neutron fluence…

Materials scienceNuclear engineeringneutron beamTP1-1185power device reliabilityBiochemistrySettore FIS/03 - Fisica Della MateriaArticleAnalytical Chemistrychemistry.chemical_compoundReliability (semiconductor)silicon carbideNeutron fluxSilicon carbideNeutronPower semiconductor deviceIrradiationElectrical and Electronic EngineeringPower MOSFETInstrumentationsingle event burnoutChemical technologySettore FIS/01 - Fisica SperimentaleNeutron radiationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Atomic and Molecular Physics and Opticschemistryfailure in timeSensors
researchProduct

Study of the glow curves of TLD exposed to thermal neutrons.

2007

The glow curves of thermoluminescent dosimeters (TLD600, TLD700 and MCP), exposed to a mixed field of thermal neutrons and gamma photons are analysed. The fluence values of thermal neutrons used, comparable with those used in radiotherapy, allow one to define the reliability of the TLDs, in particular the most sensitive MCP, in this radiation field and to get information on the dose absorbed values. The glow curves obtained have been deconvoluted using general order kinetics and the observed differences for the different LET components have been analysed. In particular, the ratio of the n(0) parameter of two different peaks seems to allow to discriminate the different contributions of neutr…

Materials sciencePhotonHot TemperatureThermoluminescenceAstrophysics::High Energy Astrophysical PhenomenaPhysics::Medical PhysicsRadiation DosageThermoluminescenceFluenceSensitivity and SpecificityRadiation ProtectionDosimetryRadiology Nuclear Medicine and imagingNeutronComputer SimulationNeutron beamNeutronsRadiationDosimeterRadiological and Ultrasound Technologybusiness.industryPublic Health Environmental and Occupational HealthReproducibility of ResultsGeneral MedicineEquipment DesignModels TheoreticalSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron temperatureEquipment Failure AnalysisComputer-Aided DesignThermoluminescent DosimetryThermoluminescent dosimeterAtomic physicsNuclear medicinebusinessBeam (structure)Radiation protection dosimetry
researchProduct

Accelerated Tests on Si and SiC Power Transistors with Thermal, Fast and Ultra-Fast Neutrons

2020

Neutron test campaigns on silicon (Si) and silicon carbide (SiC) power MOSFETs and IGBTs were conducted at the TRIGA (Training, Research, Isotopes, General Atomics) Mark II (Pavia, Italy) nuclear reactor and ChipIr-ISIS Neutron and Muon Source (Didcot, U.K.) facility. About 2000 power transistors made by STMicroelectronics were tested in all the experiments. Tests with thermal and fast neutrons (up to about 10 MeV) at the TRIGA Mark II reactor showed that single-event burnout (SEB) failures only occurred at voltages close to the rated drain-source voltage. Thermal neutrons did not induce SEB, nor degradation in the electrical parameters of the devices. SEB failures during testing at ChipIr …

Materials sciencesingle-event burnoutNuclear engineeringneutron beamlcsh:Chemical technologypower device reliability01 natural sciencesBiochemistrySettore FIS/03 - Fisica Della MateriaArticleAnalytical ChemistryTRIGAlaw.inventionchemistry.chemical_compoundsilicon carbideDeratinglaw0103 physical sciencesSilicon carbidelcsh:TP1-1185NeutronPower semiconductor deviceElectrical and Electronic EngineeringPower MOSFETInstrumentation010302 applied physics010308 nuclear & particles physicsNuclear reactorAtomic and Molecular Physics and OpticsNeutron temperatureneutron beamschemistryfailure in timeSensors
researchProduct

Precision mass measurements of neutron-rich nuclei between N=50 and 82

2012

Our knowledge of binding energies of neutron-rich nuclei has experienced a major revision during the last five years due to the introduction of Penning-trap based mass measurements. New mass values for nearly 300 nuclides produced in fission with uncertainties of 10 keV or less have become available. The data produced at three Penning trap facilities at Jyvaskyla, CERN-ISOLDE and Argonne cover all isotopic chains from Ni to Pr, except iodine. In this talk some of this data is reviewed and applied using the mass differentials such as two-neutron binding energy and odd-even staggering to probe their sensitivity on changes in nuclear structure and on the strength of the N=82 shell gap and asso…

Neutron-rich nucleiHistoryFissionPenning trapBinding energyNuclear TheoryFOS: Physical sciences01 natural sciences114 Physical sciencesEducationNuclear physics0103 physical sciencesNeutronNuclideNuclear structureHigh energy physicsNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentMass measurementsNuclear ExperimentPhysics010308 nuclear & particles physicsNuclear structureOdd-even staggeringPenning trapComputer Science ApplicationsShell gap Binding energyPairingIsotopes Neutron beams
researchProduct

Thermoluminescence response of sodalime glass irradiated with proton and neutron beams

2012

In the research field of emergency dosimeters to be used in case of accidental radiation exposure of the population, watch glass has been considered as a possible fortuitous dosimetric material. This paper reports on results obtained by thermoluminescence of glass samples exposed to neutron and proton beams. Thermoluminescent glow curves have been analyzed for each irradiation studying the modifications induced by the irradiation as a function of proton dose or neutron fluence. The glow curve in a specific temperature range has been used as dosimetric parameter. The thermoluminescence response of samples exposed to protons has been found to be linear in the dose range between 2 and 20 Gy an…

Nuclear and High Energy PhysicsMaterials scienceDosimeterThermoluminescenceRadiochemistryNeutron radiationThermoluminescenceNeutron temperatureProton beamNeutron fluxDosimetryDosimetryNeutronIrradiationNeutron beamInstrumentationWatch glasse
researchProduct

NMR relaxometry measurements of Fricke gel dosimeters exposed to neutrons

2014

Fricke infused gel matrices offer several features making them suitable for dosimetric applications; among the set here are tissue equivalence, low cost and ease of preparation. Their nuclear magnetic resonance (NMR) relaxation properties can be used as a radiation detector for the dosimetry of beams used in cancer therapy. In recent years neutron capture therapy has been resumed for the treatment of various types of cancer and it requires three-dimensional mapping of the neutron fields. In this work, we investigated this particular application through NMR relaxometry and MR imaging of Fricke gels exposed to neutrons. We analyzed both the R1 and R2 relaxation rates, which relate to the long…

Nuclear magnetic resonance relaxometryRelaxometryRadiationDosimeterChemistryPhysics::Medical PhysicsRelaxation (NMR)FluenceSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron captureGel dosimeterNuclear magnetic resonanceMagnetic resonance imagingNeutron fluxDosimetryFricke methodNeutronNeutron beam
researchProduct

Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry

2015

This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was fou…

Settore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistryGadoliniumFluenceTRIGAlaw.inventionNCT dosimetrychemistry.chemical_compoundPhenolslawCalibrationPhenolDosimetryIrradiationElectron paramagnetic resonanceNeutron beamNeutronsRadiationPhenolSettore ING-IND/18 - Fisica Dei Reattori NucleariSettore FIS/01 - Fisica SperimentaleElectron Spin Resonance SpectroscopyNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electron Paramagnetic ResonancechemistryCalibrationNuclear chemistry
researchProduct

Study of the response of phenol compounds exposed to thermal neutrons beams for Electron Paramagnetic Resonance dosimetry

2015

Abstract This paper reports the results regarding a new organic compound (IRGANOX ® 1076 phenols) with and without low content (5% by weight) of gadolinium oxide (Gd 2 O 3 ) for Electron Paramagnetic Resonance (EPR) dosimetry of neutron beams. The dependence of EPR signal as function of neutron dose was investigated in the fluence range studied between 10 11  cm −2 to 10 14  cm −2 . We evaluated also the effect of gadolinium on 60 Co gamma photon sensitivity of this organic compound. Our analysis showed that a low concentration of gadolinium oxide (of the order of 5% of the total mass of the dosimeter) can enhance the thermal neutron sensitivity more than 10 times with a small reduction of …

inorganic chemicalsRadiationDosimeterChemistrySettore ING-IND/18 - Fisica Dei Reattori NucleariSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumRadiochemistrySettore FIS/01 - Fisica Sperimentalechemistry.chemical_elementGadoliniumFluenceNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionElectron Paramagnetic ResonanceNCT dosimetryPhenolslawDosimetryNeutronIrradiationElectron paramagnetic resonanceInstrumentationNeutron beam
researchProduct